A system for producing 300-μsec bursts of 1017 metal atoms with 3-eV average energy is described. It is shown that this system can be successfully used to introduce impurities into CTR-oriented tokamaks for transport and confinement studies.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 1149-1154 |
| Number of pages | 6 |
| Journal | Review of Scientific Instruments |
| Volume | 46 |
| Issue number | 9 |
| DOIs | |
| State | Published - 1975 |
All Science Journal Classification (ASJC) codes