Startup impurity diagnostics in Wendelstein 7-X stellarator in the first operational phase

H. Thomsen, A. Langenberg, D. Zhang, G. Bertschinger, C. Biedermann, W. Biel, R. Burhenn, B. Buttenschön, K. Grosser, R. König, M. Kubkowska, O. Marchuk, N. Pablant, L. Ryc, T. S. Pedersen

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

An essential element for stationary stellarator operation is the understanding of the impurity transport behavior. Neoclassical theory predicts an impurity transport towards the plasma core for the standard ion root regime in stellarators [1,2]. The performance of a quasi-stationary device like Wendelstein 7-X stellarator (W7-X, presently in the commissioning phase in Greifswald, Germany) could be limited in case of strong impurity accumulation. Therefore, a set of plasma diagnostics is foreseen to obtain key experimental quantities for the neoclassical transport modeling as ion temperature profile, density gradients and impurity concentration [1]. The core impurity content is monitored by the High Efficiency eXtreme ultraviolet Overview Spectrometer system (HEXOS) [2], covering the wavelength range 2.5-160 nm (intermediate ionization states of all relevant heavy intrinsic impurity species) with high spectral resolution and a time resolution of 1 ms, adequate for transport analysis. Impurity radiation at shorter wave lengths (4 nm-0.06 nm) will be monitored with the SX pulse height analysis system (PHA) [3]. The ion temperature profile can be deduced from inversion of data from the High Resolution X-ray Imaging Spectrometer (HR-XIS), which measures the concentration and temperature of argon tracer gas in helium-like ionization stages [6,7,8]. A second X-ray Imaging Crystal Spectrometer (XICS), which will additionally provide the poloidal ion rotation velocity, is under preparation [8,9]. The total radiation will be measured by two bolometer cameras [10,11]. The status of the impurity diagnostics for the first operational phase in W7-X is summarized in this paper and an outlook for the next experimental campaign is given.

Original languageEnglish (US)
Article numberP10015
JournalJournal of Instrumentation
Volume10
Issue number10
DOIs
StatePublished - Oct 12 2015

All Science Journal Classification (ASJC) codes

  • Instrumentation
  • Mathematical Physics

Keywords

  • Plasma diagnostics - interferometry, spectroscopy and imaging
  • Spectrometers
  • X-ray detectors

Fingerprint

Dive into the research topics of 'Startup impurity diagnostics in Wendelstein 7-X stellarator in the first operational phase'. Together they form a unique fingerprint.

Cite this