TY - JOUR
T1 - Simple experimental methods for determining the apparent focal shift in a microscope system
AU - Bratton, Benjamin P.
AU - Shaevitz, Joshua W.
AU - Abraham, Thomas
N1 - Publisher Copyright:
© 2015 Bratton, Shaevitz. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2015/8/13
Y1 - 2015/8/13
N2 - Three-dimensional optical microscopy is often complicated by a refractive index mismatch between the sample and objective lens. This mismatch causes focal shift, a difference between sample motion and focal-plane motion, that hinders the accuracy of 3D reconstructions. We present two methods for measuring focal shift using fluorescent beads of different sizes and ring-stained fluorescent beads. These simple methods are applicable to most situations, including total internal reflection objectives and samples very close to the interface. For distances 0-1.5 μm into an aqueous environment, our 1.49-NA objective has a relative focal shift of 0.57 ± 0.02, significantly smaller than the simple n2/n1 approximation of 0.88. We also expand on a previous sub-critical angle theory by means of a simple polynomial extrapolation. We test the validity of this extrapolation by measuring the apparent focal shift in samples where the refractive index is between 1.33 and 1.45 and with objectives with numerical apertures between 1.25 and 1.49.
AB - Three-dimensional optical microscopy is often complicated by a refractive index mismatch between the sample and objective lens. This mismatch causes focal shift, a difference between sample motion and focal-plane motion, that hinders the accuracy of 3D reconstructions. We present two methods for measuring focal shift using fluorescent beads of different sizes and ring-stained fluorescent beads. These simple methods are applicable to most situations, including total internal reflection objectives and samples very close to the interface. For distances 0-1.5 μm into an aqueous environment, our 1.49-NA objective has a relative focal shift of 0.57 ± 0.02, significantly smaller than the simple n2/n1 approximation of 0.88. We also expand on a previous sub-critical angle theory by means of a simple polynomial extrapolation. We test the validity of this extrapolation by measuring the apparent focal shift in samples where the refractive index is between 1.33 and 1.45 and with objectives with numerical apertures between 1.25 and 1.49.
UR - http://www.scopus.com/inward/record.url?scp=84943178098&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84943178098&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0134616
DO - 10.1371/journal.pone.0134616
M3 - Article
C2 - 26270960
AN - SCOPUS:84943178098
SN - 1932-6203
VL - 10
JO - PloS one
JF - PloS one
IS - 8
M1 - e0134616
ER -