TY - JOUR
T1 - Pulsed vector atomic magnetometer using an alternating fast-rotating field
AU - Wang, Tao
AU - Lee, Wonjae
AU - Limes, Mark
AU - Kornack, Thomas
AU - Foley, Elizabeth
AU - Romalis, Michael
N1 - Publisher Copyright:
© The Author(s) 2025.
PY - 2025/12
Y1 - 2025/12
N2 - We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 fT/Hz (0.7 parts per billion) and angular resolutions of 6 nrad/Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.
AB - We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 fT/Hz (0.7 parts per billion) and angular resolutions of 6 nrad/Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.
UR - http://www.scopus.com/inward/record.url?scp=85218275061&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85218275061&partnerID=8YFLogxK
U2 - 10.1038/s41467-025-56668-2
DO - 10.1038/s41467-025-56668-2
M3 - Article
C2 - 39910092
AN - SCOPUS:85218275061
SN - 2041-1723
VL - 16
JO - Nature communications
JF - Nature communications
IS - 1
M1 - 1374