Abstract
The superconducting solenoid magnet for the GEM detector poses unusual fabrication and handling challenges because of its extraordinary size. It will be more than 30% larger in diameter than the largest existing particle detector coils. Each of the two coil elements that compose the air-core solenoid, will be about 19 meters in diameter and 15 meters long. Major components weighing as much as 1500 Mg must be transported and manipulated at the Interaction Region 5 (IR5) fabrication site of the SSC Laboratory as the magnets are fabricated. Because of their large size, the magnets will be fabricated, assembled and tested at special purpose facilities at the IRS site. The site-use plan must accommodate the fabrication of other detector components and the assembly of large flux shaping iron structures in a timely manner to allow subsequent testing and detector assembly. Each cold mass will be composed of twelve 45-Mg coil windings that are joined prior to assembly into the 19-m diam annular cryostat.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 2503-2506 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Magnetics |
| Volume | 30 |
| Issue number | 4 |
| DOIs | |
| State | Published - Jul 1994 |
| Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Electronic, Optical and Magnetic Materials
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Plans For Building The Largest Thin Solenoid Ever'. Together they form a unique fingerprint.Cite this