MAGNETICS DESIGN FOR RIPPLE-ASSISTED BEAM INJECTION INTO THE ISX-B AND TFTR TOKAMAKS.

Robert James Goldston, D. L. Jassby, H. H. Towner, R. H. Fowler, J. F. Lyon, J. A. Rome, Thomas G. Brown

Research output: Contribution to conferencePaperpeer-review

1 Scopus citations

Abstract

A test of ripple-assisted neutral-beam injection will be performed on the ISX-B device in 1978-79, using a low-power beam with W//b similar 10 to 20 keV, and possibly also on the TFTR device ca. 1982 with a high-power 80-keV beam. In both cases, the optimal coil configuration for establishing the required vertically asymmetric toroidal-field ripple consists of a pair of trapezoidal current loops located between the TF coils and the vacuum vessel, and bracketing the vertically injected beam. This report describes the design of the ripple coils for ISX-B, the ripple contours in the elliptical ISX-B and circular TFTR plasmas, and the objectives and parameters of the ISX-B experiment. The formation of magnetic islands in the plasma is examined for an arbitrary number of ripple-injection locations.

Original languageEnglish (US)
Pages1333-1338
Number of pages6
StatePublished - 1977
EventProc of the Symp on Eng Probl of Fusion Res, 7th - Knoxville, TN, USA
Duration: Oct 25 1977Oct 28 1977

Other

OtherProc of the Symp on Eng Probl of Fusion Res, 7th
CityKnoxville, TN, USA
Period10/25/7710/28/77

All Science Journal Classification (ASJC) codes

  • General Engineering

Fingerprint

Dive into the research topics of 'MAGNETICS DESIGN FOR RIPPLE-ASSISTED BEAM INJECTION INTO THE ISX-B AND TFTR TOKAMAKS.'. Together they form a unique fingerprint.