TY - GEN
T1 - Laboratory testing and performance verification of the CHARIS integral field spectrograph
AU - Groff, Tyler D.
AU - Chilcote, Jeffrey
AU - Kasdin, N. Jeremy
AU - Galvin, Michael
AU - Loomis, Craig
AU - Carr, Michael A.
AU - Brandt, Timothy
AU - Knapp, Gillian
AU - Limbach, Mary Anne
AU - Guyon, Olivier
AU - Jovanovic, Nemanja
AU - McElwain, Michael W.
AU - Takato, Naruhisa
AU - Hayashi, Masahiko
N1 - Publisher Copyright:
© 2016 SPIE.
PY - 2016
Y1 - 2016
N2 - The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically, the relative alignment of the lenslet array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2 as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.
AB - The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically, the relative alignment of the lenslet array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2 as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.
KW - Coronagraphy
KW - Exoplanets
KW - Extreme Adaptive Optics
KW - Integral Field Spectrograph
KW - Lenslet
UR - http://www.scopus.com/inward/record.url?scp=85007242730&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85007242730&partnerID=8YFLogxK
U2 - 10.1117/12.2233447
DO - 10.1117/12.2233447
M3 - Conference contribution
AN - SCOPUS:85007242730
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - Ground-Based and Airborne Instrumentation for Astronomy VI
A2 - Simard, Luc
A2 - Evans, Christopher J.
A2 - Takami, Hideki
PB - SPIE
T2 - Ground-Based and Airborne Instrumentation for Astronomy VI
Y2 - 26 June 2016 through 30 June 2016
ER -