TY - JOUR
T1 - High resolution muon computed tomography at neutrino beam facilities
AU - Suerfu, B.
AU - Tully, C. G.
N1 - Publisher Copyright:
© 2016 IOP Publishing Ltd and Sissa Medialab srl.
PY - 2016/2/24
Y1 - 2016/2/24
N2 - X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials.
AB - X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials.
KW - Accelerator Applications
KW - Computerized Tomography (CT) and Computed Radiography (CR)
UR - http://www.scopus.com/inward/record.url?scp=84961171841&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84961171841&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/11/02/P02015
DO - 10.1088/1748-0221/11/02/P02015
M3 - Review article
AN - SCOPUS:84961171841
SN - 1748-0221
VL - 11
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 2
M1 - P02015
ER -