Feasibility study for a high-k temperature fluctuation diagnostic based on soft x-ray imaging

X. Chen, J. Ruiz Ruiz, N. T. Howard, W. Guttenfelder, J. Candy, J. W. Hughes, R. S. Granetz, A. E. White

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

A new pseudolocal tomography algorithm is developed for soft X-ray(SXR) imaging measurements of the turbulent electron temperature fluctuations (d Te) in tokamaks and stellarators. The algorithm overcomes the constraints of limited viewing ports on the vessel wall (viewing angle) and limited number of lines of sight (LOS). This is accomplished by increasing the number of LOS locally in a region of interest. Numerical modeling demonstrates that the wavenumber spectrum of the turbulence can be reliably reconstructed, with an acceptable number of viewing angles and LOS and suitable low SNR detectors. We conclude that a SXR imaging diagnostic for measurements of turbulent d Te using a pseudolocal reconstruction algorithm is feasible.

Original languageEnglish (US)
Article number053537
JournalReview of Scientific Instruments
Volume92
Issue number5
DOIs
StatePublished - May 1 2021

All Science Journal Classification (ASJC) codes

  • Instrumentation

Fingerprint

Dive into the research topics of 'Feasibility study for a high-k temperature fluctuation diagnostic based on soft x-ray imaging'. Together they form a unique fingerprint.

Cite this