Abstract
A new electron Bernstein wave emission diagnostic consisting of a radiometer and a reflectometer was studied. The mode-conversion efficiency was calculated by using a one-dimensional full-wave code. The mode-conversion efficiency was found to be 0.5-0.8, leading to electron temperature (Te) of 200 eV.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 1453-1456 |
| Number of pages | 4 |
| Journal | Review of Scientific Instruments |
| Volume | 74 |
| Issue number | 3 II |
| DOIs | |
| State | Published - Mar 2003 |
| Externally published | Yes |
| Event | Proceedings of the 14th Topical Conference on High - Temperature Plasma Diagnostics - Madison, WI, United States Duration: Jul 8 2002 → Jul 11 2002 |
All Science Journal Classification (ASJC) codes
- Instrumentation