Abstract
To investigate the interactions between external resonant magnetic perturbations (RMPs) and a tokamak plasma, a set of saddle coils are designed for the J-TEXT. A method for designing RMP field structure based on Fourier transform is used in this paper. Since the coils will be mounted inside the vacuum vessel where the pressure is about 10 -7Pa an airproof multi-layer structure is adopted to avoid contaminating the vacuum environment. Besides, stress and thermal analysis and the AC response of magnetic field are also given.
| Original language | English (US) |
|---|---|
| Article number | 6112794 |
| Journal | IEEE Transactions on Applied Superconductivity |
| Volume | 22 |
| Issue number | 3 |
| DOIs | |
| State | Published - 2012 |
| Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Electronic, Optical and Magnetic Materials
- Condensed Matter Physics
- Electrical and Electronic Engineering
Keywords
- Fourier transform
- magnetic coils
- resonant magnetic perturbation
- tokamak
Fingerprint
Dive into the research topics of 'Design of the in-vessel magnetic coils for generating a rotating resonant magnetic perturbation on the J-TEXT Tokamak plasma'. Together they form a unique fingerprint.Cite this