Abstract
This letter presents a simplified dc-bias injection circuit utilizing a voltage mirror transformer configured in a unique way for improved equipment applicability and measurement accuracy. A mirror transformer can minimize the impact of the reflected actuation voltages on the dc source and improve the quality of the dc-bias injection. By combining the dc-bias and ac-actuation current, the traditional three-winding dc-bias measurement setup was simplified with improved accuracy and reduced equipment complexity. The dc-bias injection circuit was implemented as a part of a highly automated data acquisition system designed for fast and accurate characterization of power magnetic materials under a wide range of operating conditions.
Original language | English (US) |
---|---|
Pages (from-to) | 6608-6612 |
Number of pages | 5 |
Journal | IEEE Transactions on Power Electronics |
Volume | 39 |
Issue number | 6 |
DOIs | |
State | Published - Jun 1 2024 |
All Science Journal Classification (ASJC) codes
- Electrical and Electronic Engineering
Keywords
- Core loss
- dc-bias
- hysteresis loop
- MagNet project
- power magnetics
- soft magnetic materials